Raqamli Transformatsiya va Sun’iy Intellekt
Kardiotokografik signallarga signal sifatiga moslashuvchan dastlabki ishlov berish algoritmi va dasturiy moduli
1 Toshkent Kimyo xalqaro universiteti
2 Ma’mun universiteti
3 Urganch RANCH texnologiya universiteti qoshidagi Ranch School
Zenodo DOI: 10.5281/zenodo.23239757
Keywords
Abstract
Missing values and artifacts in cardiotocography signals directly affect the outcome of preprocessing, while fixed thresholds do not account for the local characteristics of the signal. This paper proposes an algorithm that combines a signal quality vector, adaptive artifact detection based on the local median and MAD, and the selection of a reconstruction strategy according to gap length and context quality. The architecture of its software module was designed, and a Python prototype was implemented. In a synthetic protocol based on reference segments from the CTU-UHB database, the F-measure of artifact detection at 10% signal loss increased from 0.75 to 0.96 on 520 test instances drawn from 157 test recordings. The reconstruction error on the same gap samples decreased from 1.94 to 1.77 bpm, and the error over all corrupted samples decreased from 4.55 to 2.19 bpm. The computation time per sample was several orders of magnitude shorter than the sampling interval.
References
- G. Feng, J. G. Quirk, P. M. Djuric, “Recovery of missing samples in fetal heart rate recordings with Gaussian processes,” 2017 25th European Signal Processing Conference (EUSIPCO), Kos, Greece: IEEE, Aug. 2017, pp. 261–265. doi: 10.23919/EUSIPCO.2017.8081209.
- L. Mendis, M. Palaniswami, F. Brownfoot, E. Keenan, “Computerised Cardiotocography Analysis for the Automated Detection of Fetal Compromise during Labour: A Review,” Bioengineering, vol. 10, no. 9, pp. 1007, Aug. 2023, doi: 10.3390/bioengineering10091007.
- F. N. Fritsch, R. E. Carlson, “Monotone Piecewise Cubic Interpolation,” SIAM Journal on Numerical Analysis, vol. 17, no. 2, pp. 238–246, Apr. 1980, doi: 10.1137/0717021.
- F. R. Hampel, “The Influence Curve and its Role in Robust Estimation,” Journal of the American Statistical Association, vol. 69, no. 346, pp. 383–393, June 1974, doi: 10.1080/01621459.1974.10482962.
- W. Hardle, W. Steiger, “Algorithm AS 296: Optimal Median Smoothing,” Applied Statistics, vol. 44, no. 2, pp. 258, 1995, doi: 10.2307/2986349.
- A. L. Goldberger et al., “PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals,” Circulation, vol. 101, no. 23, June 2000, doi: 10.1161/01.CIR.101.23.e215.
- C. Orphanidou, T. Bonnici, P. Charlton, D. Clifton, D. Vallance, L. Tarassenko, “Signal Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless Monitoring,” IEEE Journal of Biomedical and Health Informatics, pp. 832–838, 2014, doi: 10.1109/JBHI.2014.2338351.
- P. J. Rousseeuw, C. Croux, “Alternatives to the Median Absolute Deviation,” Journal of the American Statistical Association, vol. 88, no. 424, pp. 1273–1283, Dec. 1993, doi: 10.1080/01621459.1993.10476408.
- M. Roos-Hoefgeest Toribio, A. Garnung Menéndez, S. Roos-Hoefgeest Toribio, I. Álvarez García, “A Novel Approach to Speed Up Hampel Filter for Outlier Detection,” Sensors, vol. 25, no. 11, pp. 3319, May 2025, doi: 10.3390/s25113319.
- P. Virtanen et al., “SciPy 1.0: fundamental algorithms for scientific computing in Python,” Nature Methods, vol. 17, no. 3, pp. 261–272, 2020, doi: 10.1038/s41592-019-0686-2.
- D. Asfaw, I. Jordanov, L. Impey, A. Namburete, R. Lee, A. Georgieva, “Fetal Heart Rate Classification with Convolutional Neural Networks and the Effect of Gap Imputation on Their Performance,” in Machine Learning, Optimization, and Data Science, vol. 13810, G. Nicosia, V. Ojha, E. La Malfa, G. La Malfa, P. Pardalos, G. Di Fatta, G. Giuffrida, and R. Umeton, Eds., in Lecture Notes in Computer Science, vol. 13810. , Cham: Springer Nature Switzerland, 2023, pp. 459–469. doi: 10.1007/978-3-031-25599-1_34.
- F. A. Ghaleb, M. B. Kamat, M. Salleh, M. F. Rohani, S. Abd Razak, “Two-stage motion artefact reduction algorithm for electrocardiogram using weighted adaptive noise cancelling and recursive Hampel filter,” PLOS ONE, vol. 13, no. 11, pp. e0207176, Nov. 2018, doi: 10.1371/journal.pone.0207176.
- A. Blázquez-García, A. Conde, U. Mori, J. A. Lozano, “A Review on Outlier/Anomaly Detection in Time Series Data,” ACM Computing Surveys, vol. 54, no. 3, pp. 1–33, Apr. 2022, doi: 10.1145/3444690.
- K. Engan et al., “FHRFormer: A Self-supervised Transformer Approach for Fetal Heart Rate Inpainting and Forecasting,” 2025, arXiv. doi: 10.48550/ARXIV.2509.20852.
- F. Barzideh et al., “Estimation of Missing Data in Fetal Heart Rate Signals Using Shift-Invariant Dictionary,” 2018 26th European Signal Processing Conference (EUSIPCO), Rome: IEEE, Sept. 2018, pp. 762–766. doi: 10.23919/EUSIPCO.2018.8553110.
- S. Wong, B. Albert, M. Vatish, G. D. Jones, “CleanCTG: A deep learning model for multi-artefact detection and reconstruction in Cardiotocography,” Biomedical Signal Processing and Control, vol. 123, pp. 110654, Sept. 2026, doi: 10.1016/j.bspc.2026.110654.
- F. Francis, S. Luz, H. Wu, S. J. Stock, R. Townsend, “Machine learning on cardiotocography data to classify fetal outcomes: A scoping review,” Computers in Biology and Medicine, vol. 172, pp. 108220, Apr. 2024, doi: 10.1016/j.compbiomed.2024.108220.
- J. Spilka et al., “Using nonlinear features for fetal heart rate classification,” Biomedical Signal Processing and Control, vol. 7, no. 4, pp. 350–357, July 2012, doi: 10.1016/j.bspc.2011.06.008.
- M. E. O’Sullivan, E. C. Considine, M. O’Riordan, W. P. Marnane, J. M. Rennie, G. B. Boylan, “Challenges of Developing Robust AI for Intrapartum Fetal Heart Rate Monitoring,” Frontiers in Artificial Intelligence, vol. 4, pp. 765210, Oct. 2021, doi: 10.3389/frai.2021.765210.
- I. Campos, H. Gonçalves, J. Bernardes, L. Castro, “Fetal Heart Rate Preprocessing Techniques: A Scoping Review,” Bioengineering, vol. 11, no. 4, pp. 368, Apr. 2024, doi: 10.3390/bioengineering11040368.
- V. Chudáček et al., “Open access intrapartum CTG database,” BMC Pregnancy and Childbirth, vol. 14, no. 1, pp. 16, Dec. 2014, doi: 10.1186/1471-2393-14-16.
- R. K. Pearson, Y. Neuvo, J. Astola, M. Gabbouj, “Generalized Hampel Filters,” EURASIP Journal on Advances in Signal Processing, vol. 2016, no. 1, pp. 1–18, Dec. 2016, doi: 10.1186/s13634-016-0383-6.
- Q. Li, R. G. Mark, G. D. Clifford, “Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter,” Physiological Measurement, vol. 29, no. 1, pp. 15–32, Jan. 2008, doi: 10.1088/0967-3334/29/1/002.
- P. J. Rousseeuw, M. Hubert, “Anomaly detection by robust statistics,” WIREs Data Mining and Knowledge Discovery, vol. 8, no. 2, pp. e1236, Mar. 2018, doi: 10.1002/widm.1236.